Cleaner wearable ECG, even when people move.

Movement corrupts the heart signal a wearable records. Dr. Hamidi's PhD research built a complete answer in three steps: find the corrupted moments, confirm them, and rebuild the clean signal.

25 mm/s · 10 mm/mV · illustrative

Illustration only, not patient data.

The problem

Motion artifacts limit remote heart monitoring

A chest patch records clean ECG while the wearer is still. Walking, climbing stairs or moving the arms shifts the electrodes against the skin, and the recording fills with noise that can hide real heart events or trigger false alarms. Filtering everything all the time is no answer either: it throws away good signal along with the bad.

How it works

Find it, confirm it, clean it

flagged: likely artifact 1 · RAW ECG from the chest patch 2 · ACCELEROMETER shows the movement 3 · RECONSTRUCTED ECG after wavelet filter + autoencoder
Animation. The accelerometer shows when the wearer moves; that window is flagged as likely artifact and only that stretch is rebuilt. Illustration, not study data.

Step 1 · Detect · FNC 2023

94.7%test accuracy · 93% precision on artifact moments

Using only the device's 3-axis accelerometer, wavelet scattering features and a fine k-nearest-neighbour classifier recognise the activity and flag the moments likely to corrupt the ECG. No extra sensors are needed.

Step 2 · Confirm · ICAIMA 2023

98.8%test accuracy · AUC 0.995 for artifact moments

Feeding the ECG together with the accelerometer into the same approach makes detection sharper, so a monitor can trust its own flags.

Step 3 · Clean · ICAAI 2023

+12.64%SNR improvement · RMSE 0.0058

Flagged stretches pass through a biorthogonal wavelet filter, then a denoising autoencoder (a deep-learning model) rebuilds the ECG while keeping the shape of each heartbeat.

1. WearECG patch with a3-axis accelerometer2. SliceSplit the motion signalinto short windows3. DescribeWavelet scattering turnseach window into features4. ClassifyFine-KNN flags windowslikely to corrupt the ECG5. ActClean windows kept;flagged ones filteredor reconstructed
Figure 1. The detection pipeline from the FNC 2023 paper.

The evidence

Back to the clean signal's level

Signal strength (RMS) of the recorded ECG. Movement pushed it from 306 to 442 microvolts; after the two-step clean-up it returns to 313, within a few percent of the clean recording.

Clean ECG (driving)306 µVNoisy ECG (artifact)442 µVAfter wavelet filter382 µVAfter autoencoder313 µV
Figure 2. ECG RMS by stage, from the ICAAI 2023 paper (Table 2). Dashed line: clean recording.

Compared with published methods

MethodRMSESNR improvement
Prior study A0.0376.49%
Prior study B0.018912.57%
Prior study C0.0639.55%
Hamidi et al., two-step method0.005812.64%
3-AXIS ACCELEROMETER · motionECG · same momentsShaded: windows flagged as likely ECG artifact · illustration, not study data
Figure 3. When the wearer moves, the accelerometer shows it. Flagged windows (shaded) line up with the stretches where the ECG is distorted. Illustration, not study data.

Data: a chest-worn ECG monitor with a built-in accelerometer, recorded from one healthy adult volunteer while walking, climbing stairs, driving and clapping (about 309,000 motion samples). Results are from that controlled dataset; testing on larger and clinical groups is the next step.

Published work

Three peer-reviewed papers in 2023

With co-authors Bill Robertson and Jacek Ilow, Dalhousie University.

FNC 2023 · Halifax · Open access

A new approach for ECG artifact detection using fine-KNN classification and wavelet scattering features in vital health applications

18th International Conference on Future Networks and Communications (FNC). Procedia Computer Science, vol. 224, pp. 60–67 · doi:10.1016/j.procs.2023.09.011

ICAIMA 2023 · July 14, 2023 · Scopus-indexed

Robust ECG Artifact Noise Classification Method using Wavelet Scattering Features in Vital Health Applications

International Conference on Artificial Intelligence in Medical Applications (ICAIMA)

ICAAI 2023 · October 10, 2023

A Robust Two-Step Approach to ECG Artifact Noise Reduction

International Conference on Advance Artificial Intelligence (ICAAI 2023). International Journal of Engineering Research in Computer Science and Engineering (IJERCSE), ISSN 2394-2320

PhD thesis · Dalhousie University · 2024

Machine learning-based classification and reduction of motion artifact noise in ECG signals for wearable vital sign monitoring devices

Research stage. Halitech's ECG methods are not a medical device and have not been approved or cleared by Health Canada, the FDA or any other regulator. Nothing on this site is medical advice.

From the lab to your company

The same discipline, applied to your AI plans

Most AI projects fail for the reasons this research had to solve: unclear goals, messy data and models that look good in a demo but not in daily use. The habits behind these papers are the ones Halitech brings to companies adopting AI.

  • In the research

    Define the exact moment that matters

    Not "clean the ECG" but "find the seconds when movement corrupts it". For you: pick one decision or task where AI can measurably help, before buying any tool.

  • In the research

    Use the sensors you already have

    The method works with the accelerometer already inside the device. For you: start with the data your systems already collect; most companies have more than they think.

  • In the research

    Collect data with a protocol

    Every activity was labelled and timed. For you: a short data audit shows whether your records can support AI, and what to fix first.

  • In the research

    Choose the simplest model that works

    A fine-KNN classifier beat heavier approaches on this data, and deep learning was used only where it earned its place. For you: right-sized tools, lower cost, fewer surprises.

  • In the research

    Measure honestly

    Accuracy, precision and false alarms are reported separately, with the dataset's limits stated. For you: pilots with clear success measures before scaling.

  • In the research

    Design for the real device

    The method targets wearables with limited power and no extra sensors. For you: plans that fit your people, budget and systems, not a lab.